Back
|
Premium Flex Cable
PRIMARY: (See TABLE I)
Bare Copper
Polyester Elastomer Insulation
Color Code:
1-3. Black with White Printed Numbers 4. Green/Yellow
OVERALL CABLE:
Primaries Required: 4
FR-Fibrillated Polypropylene Filler
Expanded Polytetrafluoroethylene Tape, 50% Overlap
JACKET:
Separator Tape - Required
C&M Duralon™ (See TABLE 1) Wall Thickness
Final Diameter (See TABLE I)
Color: Black
Print Legend (White Ink): C&M CORPORATION E135238 xx AWG 4/C (UL) TYPE TC-ER 600V 90°C FT4 OR AWM 20626 --- c(UL) CIC 90°C DRY FT4 ---PREMIUM CONTINUOUS FLEXING RoHS
Note: xx = AWG |
INDUSTRY STANDARD REQUIREMENTS:
RoHS Compliant per European Union Directive 2002/95/EC
SAFETY CERTIFICATIONS: UL Listing: Type TC-ER / WTTC in accordance with Article 336 of the National Electric Code.
MECHANICAL REQUIREMENTS:
Continuous Flex  |
| | PRIMARY | JACKET |
| C&M Part # | AWG & Standing | PVC Wall | OD | Wall | Nom OD |
80041 |
6 (19x35/34) | .022" | .259" | .065" | .772" ± .025" |
80042 |
8 (7x59/34) | .022" | .211" | .065" | .656" ± .020" |
80043 |
10 (7x37/34) | .016" | .164" | .050" | .511" ± .020" |
80044 |
12 (7x24/34) | .011" | .124" | .050" | .414" ± .015" |
80045 |
14 (105/34) | .011" | .094" | .050" | .342" ± .010" |
80046 |
16 (65/34) | .011" | .081" | .050" | .311" ± .010" |
♦ Tested to 20 million cycles
♦ Note: When ordering the C&M Product, use the individual part number.
♦ Duralon™: Thermoplastic rubber blend with over 15 years of proven durability in chemical and abrasion resistance experienced during high abuse and continous flex applications. |
|